Home |  My Account  |  Cart  |  About Vecmar  |  Contact Us
Call us toll free: 800-457-8499
International: 440-953-1119
  If you're not impressed we haven't succeeded! 
PRODUCTS
BRANDS
INDUSTRIES
SERVICES
REMANUFACTURE
SUPPORT
QUOTE ME!
WE BUY
  ADDS
  Boundless
  DEC
  Digi
  HP
  IBM
  Lexmark
  Link
  NCR
  Okidata
  Printronix
  Tallygenicom
  Unisys
  Wyse

 

Download VFS Brochure

Looking for Fulfillment?

Home > Brands > NCR > NCR Servers, Systems and Upgrades
NCR WorldMark 4700 servers and upgrades: Processing Node Information NCR Worldmark 4700 Servers, Systems and Upgrades from Vecmar Computer Solutions

Vecmar is an Authorized NCR Distributor of

NCR WorldMark 4700 Server
Processing Node Information



Call or email now for a quote or to place an order.



Thanks for choosing Vecmar, one of the largest custom configuration houses in North America, specializing in NCR systems exclusively.



NCR WorldMark 4700 Processing Node Information

Two processing nodes are resident in a standard rack configuration. In a system rack with BYNET present, the nodes are the fourth and fifth chassis from the top of the rack, between the BYNET and UPS chassis. Node chassis IDs are always "4" and "5," top and bottom respectively, whether or not the BYNET chassis ("2" and "3") are present.

NCR WorldMark 4700 Node Component Summary

WorldMark 4700 Processing Node Component Type

WorldMark 4700 Processing Node Component Description

Multiple processor support Two slots (primary and secondary) for processor boards; four 200 MHz Pentium Pro microprocessors with integrated 512 KB write-back cache (two on each processor board).
Upgradeable memory One slot for memory board. 4 GB memory board supports 16 DIMM devices for a minimum memory size of 512 MB up to a total of 4 GB of memory.
Adapter board support 10 expansion bus slots, 6 PCI and 4 EISA (supports ISA).

PCI is dual bus architecture. Bus #0 (primary) connects the processor bus to a PCI/EISA bridge and three PCI connectors (slots 1, 2, 3). Bus #1connects the processor bus to two on-board fast/wide SCSI controllers and three PCI connectors (slots 4, 5, 6).

Standard adapter configuration includes:

  • BYNET adapters -- 2 BPCI boards or 1 BIC2G board with dual ports. Each cabled to separate BYNET chassis for redundancy and high availability. Either BYNET adapter type enables BYNET communication with all other nodes in system.
  • 2 NCR PCI Quad SCSI (PQS) boards (unshared). Each on separate PCI bus for high availability. PQS enables connection of up to 16 SCSI devices per bus, 4 buses per board.
  • 1 EISA or PCI Ethernet board. Provides LAN connection to AWS. (Only two nodes in system require this board to create AWS LAN gateway to other nodes through BYNET connections.)
On-board SCSI controllers Two embedded, fast and wide PCI SCSI-2 controllers (Adaptec AIC-7880), Channels A and B, integrated as PCI bus masters. Channel A to SCSI drive backplane for internal SCSI drives.
Hot swap-capable SCSI backplane with 6 bays The SCSI backplane has 6 hot-swap bays for 3.5-inch SCSI-2 hard drives.

The backplane supports wide and fast SCSI-2 devices that use the industry standard 80-pin Single Connector Attach (SCA) connector.

Standard drive configuration is three 9-GB drives (max. 6 supported). For storage of operating environment and applications programs only.

The SCSI drive backplane is configured as one SCSI bus. The backplane automatically terminates the full 16-bit-wide bus.
Four removable media drive bays Four externally accessible 5.25-inch half-height bays are available for diskette, CD-ROM, and/or tape drives. 3.5-inch diskette drive is mounted in 5.25-inch carrier for insertion in any of these bays.
Server Management Board (SMB) with network card Microcontroller that handles management functions within the node, including power control, reset, environmental monitoring, and post code reporting.Network card provides the MLAN connection to the service subsystem.

The network card interfaces to the service subsystem through a passthrough board.
Power subsystem Two self-contained 625-watt autoranging power supplies. Redundant, hotpluggable, in a 1+1 configuration. Each power supply docks into a power distribution backplane inside the node chassis. The backplane provides connections for the DC power signals and status and control functions, such as server management features (quantity, location, and reporting of installed and failed supplies), through I2C control.
Dual AC Two separate AC feeds, each connecting to one of the two power supplies, accommodates dual AC input for high availability.
Cooling Pair of dual fan assemblies at front of node chassis provide cooling for boards and drives; redundancy in case of single fan failure. Air flow is from front to rear.
Video Integrated super VGA controller chip with 1 MB of video memory.
Security Intrusion sensor (on inside wall making contact with top cover of node chassis) disables power to node when top cover is removed.

(Note: BIOS firmware also allows for password enable; secure mode power-off disable.)

Firmware and utilities (referred to as "server software") installed on the processing node of the NCR WorldMark 4700:

WorldMark 4700 Server Software Type

WorldMark 4700 Server Software Description

BIOS Flash memory-based BIOS (Basic Input/Output System) implemented through a 512K flash device on system board.
Setup Utility Contained within the system BIOS, always available locally and remotely. Provides for very basic system configuration, and has support for additional features.
Diagnostic Partition Logical partition on the system hard disk, containing essential utilities for software maintenance and system configuration. Allows for remote execution of Diagnostics, SCU and other repair utilities, as well as software maintenance and system configuration tasks.
System Configuration Utility (SCU) Configures the system board hardware and I/O adapters. Console redirection is supported via the Com 1 and Com 2 serial ports.

NCR WorldMark 4700 component firmware and software installed on the node:

WorldMark 4700 Node Component Firm/Software Type

WorldMark 4700 Node Component Firm/Software Description

Chassis enabling firmware Enables front panel logic and SCSI hot-plug backplane. Intel microcode.
SMB firmware Controls the SMB initialization, power-on diagnostics, firmware initialization, SMB heartbeat, and console redirection. Also provides for monitoring and controlling of the processing node, event handling, and configuration.
SMB network card firmware Controls the SMB network card initialization, power-on diagnostics, firmware initialization, SMB heartbeat, network card heartbeat, and the BCL command transport to the SMB. Also provides for the monitoring of external UPS heartbeats, AC fail in the processing node, event handling, and configuration.
BYNET driver software BYNET Link Manager (BLM). UNIX STREAMS device driver that manages the physical device which connects a UNIX processor node to a BYNET.
BYNET adapter diagnostic software BYNET utility program that performs BYNET adapter Level 0 diagnostics through a user interface.
BYNET Administrative Menu (BAM) software BYNET utility program that determines BYNET configuration and connections from node perspective for current installation.

Need something you don't see listed above?

Call 800-457-8499 or email us for information and pricing on systems and upgrades not listed.

Questions about the NCR WorldMark 4700 Server?

For more information on NCR WorldMark 4700 server call us at 800-457-8499 or email us.

Order Your NCR WorldMark 4700 Server and Upgrades

Order your NCR WorldMark 4700 server and upgrades now! For more information call 800-457-8499 or email us. Your purchase order, with credit approval, is welcome; as well as all major credit cards. Remember, you'll get FREE technical service with every product you buy from Vecmar.


Be first: Special Offers & New Products. Sign up today.

How do you prefer to receive your newsletter?
Text
HTML
We value your privacy!
Read current issue
No Risk Hardware Trial
Professional Services
Industry Leading Warranties
Hardware Repair
Hardware Remanufacture
Schedule Service
Hardware Trade-in Plan
ADDS 4000/260 Terminal
Boundless 4000 Terminal
DEC VT 420 Terminal
DEC VT 510 Terminal
IBM 3151 Terminal
IBM 3153 Terminal
Genicom 3810S Printer
Genicom 3840ep Printer
Link MC5 Terminal
Link Max700 Terminal
NCR S2600 Server
NCR 2900 Terminal
Okidata 320 Turbo Printer
Okidata 395 Printer
Tally T2155 Printer
Wyse 60 Terminal
Wyse 55 Terminal
Wyse 520 Terminal
Wyse WY-GPT Terminal
Winpath WP3230-WB Thin Client
Winpath WP3200-WB Thin Client
Winpath WP3360-WB Thin Client
NCR  |  WYSE  |  UNISYS  |  ADDS  |  BOUNDLESS  |  LEXMARK  | LINK  |  DEC  |  IBM  |  OKIDATA  |  GENICOM  |  TALLY  |  DIGI
VECMAR Computer Solutions | 7595 Jenther Drive | Mentor, Ohio 44060 USA
(800) 457-8499 | Int'l (440) 953-1119 | Fax (440) 953-8341
Site Map | Links | Terms of Sale | Use of this site indicates that you accept the Terms of Use.
Copyright 1991-2003 VECMAR Computer Solutions
Hours: 9 am to 6 pm (Eastern Standard Time)